Soft Start: 600V AC, 66 A Output Current, With Bypass, NEMA 1, 60/50 Hz, Three Phase, 24V DC
Soft Start: 600V AC, 66 A Output Current, With Bypass, NEMA 1, 60/50 Hz, Three Phase, 24V DC

Product Image

Soft Start: 600V AC, 66 A Output Current, With Bypass, NEMA 1, 60/50 Hz, Three Phase, 24V DC

Manufacturer: EATON
Mfr. Model # S811+N66N3S
In Stock
$6,454.00 Save 12%
$5,651.05 /each
Earn 5651 points for this item ($56.51 for your next purchase!) REGISTER NOW TO EARN!
ETA 5-7 BUSINESS DAYS
Request quantity discount pricing
You're Viewing
Soft Start: 600V AC, 66 A Output Current, With Bypass, NEMA 1, 60/50 Hz, Three Phase, 24V DC
EATON Soft Start: 600V AC, 66 A Output Current, Wit...
Mfr # S811+N66N3S
$5,651.05
Customers Also Viewed

No related products found.

Product Details

Brand EATON
zz DELETE - Item Soft Start
Output Power @ Three-Phase - 480V 40 hp
Overall Width 2.66 in
Starting Torque 0% to 83%
Storage Protection Code A
Display Sell UOM EA
Display Qty 1
Contains California Prop 65 Carcinogen N
Enclosure Rating NEMA 1
EnvironmentallyPreferable_Indicator N
Freight Class Code 18
Product Type Soft Start
Output Current 66 A
Safety Data Sheet (SDS) Applicable? N
yy DELETE - Ramp Time 0 to 180 sec.
Frequency 60/50 Hz
Phase Three
Number of Inputs - Analog 1
Function Type Start/Stop
Ozone Depleting Substance N
Protects Motor Overload, Jam, Stall, Pole Over Temperature, Phase Loss, Phase Imbalance, Ability to Alarm Without Tripping for Critical Situations, Ability for Advance Communications for Critical Load Monitoring
Output Power @ Three-Phase - 208V 15 hp
Overall Height 7.36 in
yy DELETE - Stop Time 0 to 60 sec
Manufacturer Part Number S811+N66N3S
Stop Time - Minimum 0 sec
Communication Protocols Supported Modbus RTU
yy DELETE - Input and Output Types Analog Input, (9) Function Based Digital Inputs/Outputs, (3) 6A Relay Outputs
Number of Outputs - Relay 3
Should Sales be Restricted by Region? N
Input Voltage 600V AC
Number of Outputs - Digital 9
Output Power @ Three-Phase - 230V 20 hp
Output Power @ Three-Phase - 240V 20 hp
Output Power [Merch] 15 hp Output Power @ Three-Phase - 208V ; 20 hp Output Power @ Three-Phase - 230V ; 20 hp Output Power @ Three-Phase - 240V ; 40 hp Output Power @ Three-Phase - 460V ; 40 hp Output Power @ Three-Phase - 480V ; 50 hp Output Power @ Three-Phase - 575V
Number of Inputs - Digital 9
Control Voltage 24V DC
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Ramp Time - Minimum 0 sec
yy DELETE - Output Power 40 hp @ 3 Phase, 480V AC, 50 hp @ 3 Phase, 575V AC, 15 hp @ 3 Phase, 200V AC, 20 hp @ 3 Phase, 240V AC
Stop Time - Maximum 60 sec
Ramp Time - Maximum 180 sec
Application Constant and Variable Torque
Sub-brand Soft Starts
Overall Depth 6.5 in
zz DELETE - Output Voltage 600V AC
Bypass Design With Bypass
Standards UL 508, CSA 22.2-14-1995, GB14048, IEC/EN 60947-4-2
Output Power @ Three-Phase - 575V 50 hp
Output Power @ Three-Phase - 460V 40 hp
Includes Communication Port Yes
Product Powered by Fossil Fuel N
Is this a Hazardous Material Product? N
Contains California Prop 65 Reproductive Toxicant N
Mfr. Model # S811+N66N3S
Description

Soft Start, With Bypass

Catalog Page 0