Abrasives Adhesives, Sealants and Tape Appliances Building Supplies Carts & Trucks Clamping, Workholding & Positioning Cleaning and Janitorial Electrical Electronics & Batteries Emergency Preparedness Products Extended Warranty Fasteners Fasteners & Hardware Fire Protection Fleet & Vehicle Maintenance Fleet Maintenance Food Service & Food Processing Foodservice & Retail Furnishings, Appliances & Hospitality Furnishings, Hospitality & Building Materials Furniture Furniture & Decor Hand Tools Hardware Holemaking Hose, Tube, Fittings & Valves HVAC HVAC & Fans HVAC and Refrigeration Hydraulics Indexable Cutting Tools Janitorial & Facility Maintenance Lab Supplies Lighting Lighting & Electrical Lubricants, Coolants & Fluids Lubrication Machinery Machining Marking & Labeling Material Handling Material Handling & Storage Measuring & Inspecting Medical & Laboratory Milling Motion Control & Fluid Power Motors Motors & Power Transmission NON Web - Customer Specific Items Office & School Supplies Office Supplies Outdoor Equipment Outdoor Furniture Packaging & Shipping Paints, Equipment and Supplies Pipe, Hose, Tube & Fittings Plumbing Plumbing & Pumps Plumbing, Pumps & Filtration Pneumatics Power Tools Power Transmission Pumps Raw Materials Reference Books & Incentive Gifts Retail Supplies & Store Operations Safety Safety & Security Saw Blades Security Shipping & Office Supplies Storage & Shelving Tapes & Adhesives Test Instruments Threading Tool Holding Tools Tools & Instruments Turning & Boring Uncategorized Vehicle Maintenance Welding Welding & Soldering Workbenches & Shop Desks View All Categories
Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Drywell: 32°F to 2696°F /-196°C to 1480°C, 384.8°F to 1220°F /-196°C to 660°C, Adj Set Point
Drywell: 32°F to 2696°F /-196°C to 1480°C, 384.8°F to 1220°F /-196°C to 660°C, Adj Set Point

Product Image

Drywell: 32°F to 2696°F /-196°C to 1480°C, 384.8°F to 1220°F /-196°C to 660°C, Adj Set Point

Manufacturer: FLUKE
Mfr. Model # 9143-B-156
In Stock
$10,639.00 Save 21%
$8,447.00 /each
Earn 8447 points for this item ($84.47 for your next purchase!) REGISTER NOW TO EARN!
1 day
Request quantity discount pricing
You're Viewing
Drywell: 32°F to 2696°F /-196°C to 1480°C, 384.8°F to 1220°F /-196°C to 660°C, Adj Set Point
FLUKE Drywell: 32°F to 2696°F /-196°C to 1480°C, 38...
Mfr # 9143-B-156
$8,447.00
Customers Also Viewed

No related products found.

Product Details

Catalog Page 572
Brand FLUKE
Interchangeable Insert Yes
Process Connections Included RTD, Thermocouple, Transmitter
Typical Cooling Time 32 min (350 Degrees to 33 Degrees C), 14 min (350 Degrees to 100 Degrees C)
RTD Temperature Celsius - Minimum -196 Degrees C
Well Depth 5.91 in
Calibrator Weight 16 lb
Overall Width 7.31 in
Overall Height 11.41 in
For Thermocouple Type Type B, Type E, Type J, Type K, Type R, Type S, Type T
Display Resolution 0.01 Degrees F
Temperature Set Points 350 Degrees C, 30 Degrees C
Thermocouple Temperature Range 32 Degrees F to 2696 Degrees F ; -196 Degrees C to 1480 Degrees C
For Stem Diameter 3/8 in, (2) 3/16 in, 1/8 in, (2) 1/4 in
Stabilization Time 10 min
Thermocouple Temperature Fahrenheit - Minimum 32 Degrees F
Ozone Depleting Substance N
Set Point Style Adjustable
Thermocouple Temperature Fahrenheit - Maximum 2696 Degrees F
Insert Hole Diameter 3/16 in, 3/8 in, 1/4 in, 1/8 in
Voltage 100 to 115V, 230V
Product Powered by Fossil Fuel N
RTD Temperature Fahrenheit - Minimum 384.8 Degrees F
Storage Protection Code A
Number of Insert Holes 6
Includes NIST-Traceable Certificate No
Manufacturer Part Number 9143-B-156
Contains California Prop 65 Carcinogen N
Contains California Prop 65 Reproductive Toxicant N
Typical Heating Time 5 min (33 Degrees to 350 Degrees C)
Overall Depth 11.61 in
RTD Temperature Fahrenheit - Maximum 1220 Degrees F
Display Qty 1
Number of Inserts Included 1
EnvironmentallyPreferable_Indicator N
Typical Uniformity +/-0.04 Degrees C at 33 Degrees C, +/-0.1 Degrees C at 200 Degrees C, +/-0.2 Degrees C at 350 Degrees C, +/-0.01 Degrees C at 33 Degrees C, +/-0.015 Degrees C at 200 Degrees C, +/-0.02 Degrees C at 350 Degrees C
For RTD Type 3-Wire, 4-Wire, 2-Wire, Pt 100 (385)
Safety Data Sheet (SDS) Applicable? N
Should Sales be Restricted by Region? N
RTD Temperature Range 384.8 Degrees F to 1220 Degrees F ; -196 Degrees C to 660 Degrees C
Standards NVLAP Accredited
Stability +/-0.02 Degrees C at 200 Degrees C, +/-0.03 Degrees C at 350 Degrees C, +/-0.02 Degrees C at 33 Degrees C
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Sensor Technology RTD
Thermocouple Temperature Celsius - Maximum 1480 Degrees C
Thermocouple Temperature Celsius - Minimum 0 Degrees C
Is this a Hazardous Material Product? N
Power Source Plug-In
Interface RS-232
Calibrator Accuracy +/-0.2 Degrees C (Display - Full Range)
Display Sell UOM EA
RTD Temperature Celsius - Maximum 660 Degrees C
Freight Class Code 43
Single Well/Dual Well Single Well
Insert Type Included B
Mfr. Model # 9143-B-156
Description

DrywalTempCalib, Plug-In, 384.8, 1220F

Catalog Page 572