657-600-0865 | support@kddepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: Power Vented, 280, 000 BtuH Heating Capacity Output, Bottom
Gas-Fired Duct Furnace: Power Vented, 280, 000 BtuH Heating Capacity Output, Bottom

Product Image

Gas-Fired Duct Furnace: Power Vented, 280, 000 BtuH Heating Capacity Output, Bottom

Manufacturer: DAYTON
Mfr. Model # 6RJV6
In Stock
$5,178.00 Save 14%
$4,430.90 /each
Earn 4430 points for this item ($44.30 for your next purchase!) REGISTER NOW TO EARN!
40 days
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: Power Vented, 280, 000 BtuH Heating Capacity Output, Bottom
DAYTON Gas-Fired Duct Furnace: Power Vented, 280, 00...
Mfr # 6RJV6
$4,430.90
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Heating Method Fan Forced
Mounting Height 8 ft
Thermostat Included Thermostat Not Included
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Overall Height 37-3/4 in
Max. External SP 0.9" WC
Air Temperature Rise [Number] 30 Degrees F
Product Powered by Fossil Fuel N
Freight Class Code 18
Gas Connection Type Male NPT
Required Air Flow 3,241 cfm
Overall Width 42-5/8 in
Service Access Location Bottom
Heater Voltage 115 V AC
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Standards ETL Certified
Air Flow @ 65(F) Rise 4,000 cfm
Venting Vented
Contains California Prop 65 Reproductive Toxicant N
Indoor Air Discharge Width 40-1/4 in
Manufacturers Warranty Length 1 yr
CEC Title 20 Applicable Y
Air Flow @ 80(F) Rise 3,200 cfm
CEC Title 20 Compliant? Y
Primary Heat Exchanger Material Aluminized Steel
Maximum Amperage 1.9 A
Safety Data Sheet (SDS) Applicable? N
Flue Diameter 6 in
Air Flow 8642 cfm
Ignition Type Direct Spark
Heat Exchanger Gauge 20 ga
Overall Depth 37 in
Vent Type Power
CEC Title 20 MAEDbS Certified Y
Should Sales be Restricted by Region? N
Is this a Hazardous Material Product? N
Contains California Prop 65 Carcinogen N
EnvironmentallyPreferable_Indicator N
Combustion Type Open Combustion
Heating Capacity Output 280,000 BtuH
Burner Air Inlet Size 6 in
Fuel Type Natural Gas
Ozone Depleting Substance N
Gas Connection Size 3/4 in
Heating Capacity Input 350,000 BtuH
Furnace Type Power Vented
Indoor Air Discharge Height 19 in
Storage Protection Code A
Frequency 60 Hz
Mfr. Model # 6RJV6
Description

Gas Fired Dct Furnace, 3/4" M NPT, 8642cfm

Catalog Page 0