657-600-0865 | support@kddepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: Power Vented, 240, 000 BtuH Heating Capacity Output, Bottom
Gas-Fired Duct Furnace: Power Vented, 240, 000 BtuH Heating Capacity Output, Bottom

Product Image

Gas-Fired Duct Furnace: Power Vented, 240, 000 BtuH Heating Capacity Output, Bottom

Manufacturer: DAYTON
Mfr. Model # 6RJW2
In Stock
$6,096.00 Save 15%
$5,172.31 /each
Earn 5172 points for this item ($51.72 for your next purchase!) REGISTER NOW TO EARN!
40 days
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: Power Vented, 240, 000 BtuH Heating Capacity Output, Bottom
DAYTON Gas-Fired Duct Furnace: Power Vented, 240, 00...
Mfr # 6RJW2
$5,172.31
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
CEC Title 20 Applicable Y
Ozone Depleting Substance N
Product Powered by Fossil Fuel N
Burner Air Inlet Size 6 in
Ignition Type Direct Spark
Is this a Hazardous Material Product? N
Heating Capacity Input 300,000 BtuH
Indoor Air Discharge Width 34-3/4 in
Air Temperature Rise [Number] 30 Degrees F
Overall Depth 37 in
Primary Heat Exchanger Material 409 Stainless Steel
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
CEC Title 20 Compliant? Y
Gas Connection Type Male NPT
Vent Type Power
Indoor Air Discharge Height 19 in
Gas Connection Size 3/4 in
Standards ETL Certified
Freight Class Code 18
Service Access Location Bottom
Manufacturers Warranty Length 1 yr
Combustion Type Open Combustion
Thermostat Included Thermostat Not Included
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Frequency 60 Hz
Should Sales be Restricted by Region? N
Contains California Prop 65 Carcinogen N
Overall Width 37-1/8 in
EnvironmentallyPreferable_Indicator N
Safety Data Sheet (SDS) Applicable? N
Heating Method Fan Forced
Mounting Height 8 ft
CEC Title 20 MAEDbS Certified Y
Heating Capacity Output 240,000 BtuH
Required Air Flow 2,778 cfm
Maximum Amperage 1.9 A
Heater Voltage 115 V AC
Contains California Prop 65 Reproductive Toxicant N
Storage Protection Code A
Air Flow @ 65(F) Rise 3,300 cfm
Venting Vented
Max. External SP 0.9" WC
Air Flow 7407 cfm
Flue Diameter 6 in
Heat Exchanger Gauge 20 ga
Fuel Type Natural Gas
Overall Height 37-3/4 in
Air Flow @ 80(F) Rise 2,700 cfm
Furnace Type Power Vented
Mfr. Model # 6RJW2
Description

Gas Fired Dct Furnace, 3/4" M NPT, 7407cfm

Catalog Page 0