657-600-0865 | support@kddepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: Power Vented, 120, 000 BtuH Heating Capacity Output, Side
Gas-Fired Duct Furnace: Power Vented, 120, 000 BtuH Heating Capacity Output, Side

Product Image

Gas-Fired Duct Furnace: Power Vented, 120, 000 BtuH Heating Capacity Output, Side

Manufacturer: DAYTON
Mfr. Model # 6RJW6
In Stock
$3,388.00 Save 12%
$2,967.13 /each
Earn 2967 points for this item ($29.67 for your next purchase!) REGISTER NOW TO EARN!
40 days
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: Power Vented, 120, 000 BtuH Heating Capacity Output, Side
DAYTON Gas-Fired Duct Furnace: Power Vented, 120, 00...
Mfr # 6RJW6
$2,967.13
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Mounting Height 8 ft
Heat Exchanger Gauge 20 ga
Product Powered by Fossil Fuel N
Frequency 60 Hz
Heating Capacity Input 150,000 BtuH
Storage Protection Code A
Air Temperature Rise [Number] 30 Degrees F
Air Flow @ 65(F) Rise 1,500 cfm
Thermostat Included Thermostat Not Included
Ignition Type Direct Spark
Gas Connection Size 1/2 in
Required Air Flow 1,389 cfm
Contains California Prop 65 Reproductive Toxicant N
Heating Method Fan Forced
Service Access Location Side
CEC Title 20 Applicable Y
Heater Voltage 115 V AC
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Furnace Type Power Vented
Combustion Type Open Combustion
Freight Class Code 18
Max. External SP 0.75" WC
Primary Heat Exchanger Material Aluminized Steel
Air Flow 3704 cfm
Indoor Air Discharge Height 19 in
CEC Title 20 MAEDbS Certified Y
Venting Vented
EnvironmentallyPreferable_Indicator N
Vent Type Power
Indoor Air Discharge Width 18-1/4 in
Manufacturers Warranty Length 1 yr
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Overall Width 20-5/8 in
Safety Data Sheet (SDS) Applicable? N
Burner Air Inlet Size 5 in
Contains California Prop 65 Carcinogen N
Overall Height 37-3/4 in
Ozone Depleting Substance N
Is this a Hazardous Material Product? N
CEC Title 20 Compliant? Y
Overall Depth 37 in
Heating Capacity Output 120,000 BtuH
Standards ETL Certified
Maximum Amperage 1.9 A
Flue Diameter 4 in
Air Flow @ 80(F) Rise 1,700 cfm
Gas Connection Type Male NPT
Fuel Type Natural Gas
Should Sales be Restricted by Region? N
Mfr. Model # 6RJW6
Description

Gas Fired Dct Furnace, 1/2" M NPT, 3704cfm

Catalog Page 0