657-600-0865 | support@kddepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: Power Vented, 240, 000 BtuH Heating Capacity Output, Side
Gas-Fired Duct Furnace: Power Vented, 240, 000 BtuH Heating Capacity Output, Side

Product Image

Gas-Fired Duct Furnace: Power Vented, 240, 000 BtuH Heating Capacity Output, Side

Manufacturer: DAYTON
Mfr. Model # 6RJW9
In Stock
$4,856.00 Save 20%
$3,865.10 /each
Earn 3865 points for this item ($38.65 for your next purchase!) REGISTER NOW TO EARN!
ETA 60-90 DAYS
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: Power Vented, 240, 000 BtuH Heating Capacity Output, Side
DAYTON Gas-Fired Duct Furnace: Power Vented, 240, 00...
Mfr # 6RJW9
$3,865.10
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Required Air Flow 2,778 cfm
Flue Diameter 6 in
Freight Class Code 18
Overall Depth 37 in
Ozone Depleting Substance N
Safety Data Sheet (SDS) Applicable? N
Air Flow 7407 cfm
CEC Title 20 Compliant? Y
Heating Capacity Output 240,000 BtuH
Vent Type Power
Should Sales be Restricted by Region? N
Storage Protection Code A
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Frequency 60 Hz
Primary Heat Exchanger Material Aluminized Steel
Gas Connection Size 3/4 in
Ignition Type Direct Spark
Combustion Type Open Combustion
Heating Method Fan Forced
Furnace Type Power Vented
Mounting Height 8 ft
Air Flow @ 80(F) Rise 2,700 cfm
EnvironmentallyPreferable_Indicator N
Burner Air Inlet Size 6 in
Contains California Prop 65 Reproductive Toxicant N
Max. External SP 0.9" WC
Overall Width 37-1/8 in
Manufacturers Warranty Length 1 yr
CEC Title 20 MAEDbS Certified Y
CEC Title 20 Applicable Y
Indoor Air Discharge Width 34-3/4 in
Maximum Amperage 1.9 A
Indoor Air Discharge Height 19 in
Contains California Prop 65 Carcinogen N
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Gas Connection Type Male NPT
Thermostat Included Thermostat Not Included
Heat Exchanger Gauge 20 ga
Venting Vented
Is this a Hazardous Material Product? N
Heater Voltage 115 V AC
Product Powered by Fossil Fuel N
Fuel Type Natural Gas
Air Flow @ 65(F) Rise 3,300 cfm
Air Temperature Rise [Number] 30 Degrees F
Overall Height 37-3/4 in
Service Access Location Side
Heating Capacity Input 300,000 BtuH
Standards ETL Certified
Mfr. Model # 6RJW9
Description

Gas Fired Dct Furnace, 3/4" M NPT, 7407cfm

Catalog Page 0