657-600-0865 | support@kddepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: Power Vented, 120, 000 BtuH Heating Capacity Output, Side
Gas-Fired Duct Furnace: Power Vented, 120, 000 BtuH Heating Capacity Output, Side

Product Image

Gas-Fired Duct Furnace: Power Vented, 120, 000 BtuH Heating Capacity Output, Side

Manufacturer: DAYTON
Mfr. Model # 6RJX3
In Stock
$3,866.00 Save 16%
$3,228.28 /each
Earn 3228 points for this item ($32.28 for your next purchase!) REGISTER NOW TO EARN!
40 days
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: Power Vented, 120, 000 BtuH Heating Capacity Output, Side
DAYTON Gas-Fired Duct Furnace: Power Vented, 120, 00...
Mfr # 6RJX3
$3,228.28
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Heater Voltage 115 V AC
EnvironmentallyPreferable_Indicator N
Burner Air Inlet Size 5 in
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
CEC Title 20 Compliant? Y
Venting Vented
Is this a Hazardous Material Product? N
Overall Width 20-5/8 in
Storage Protection Code A
Flue Diameter 4 in
Product Powered by Fossil Fuel N
Freight Class Code 18
Overall Depth 37 in
Thermostat Included Thermostat Not Included
Contains California Prop 65 Carcinogen N
Furnace Type Power Vented
Heat Exchanger Gauge 20 ga
Gas Connection Size 1/2 in
Indoor Air Discharge Height 19 in
Required Air Flow 1,389 cfm
Heating Capacity Input 150,000 BtuH
Air Flow @ 80(F) Rise 1,700 cfm
Max. External SP 0.75" WC
Air Temperature Rise [Number] 30 Degrees F
Service Access Location Side
Frequency 60 Hz
Heating Method Fan Forced
Contains California Prop 65 Reproductive Toxicant N
Manufacturers Warranty Length 1 yr
Primary Heat Exchanger Material 409 Stainless Steel
Ignition Type Direct Spark
Maximum Amperage 1.9 A
Vent Type Power
Overall Height 37-3/4 in
Should Sales be Restricted by Region? N
Air Flow 3704 cfm
Gas Connection Type Male NPT
Fuel Type Natural Gas
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Ozone Depleting Substance N
Mounting Height 8 ft
CEC Title 20 Applicable Y
Air Flow @ 65(F) Rise 1,500 cfm
Combustion Type Open Combustion
CEC Title 20 MAEDbS Certified Y
Indoor Air Discharge Width 18-1/4 in
Standards ETL Certified
Heating Capacity Output 120,000 BtuH
Safety Data Sheet (SDS) Applicable? N
Mfr. Model # 6RJX3
Description

Gas Fired Dct Furnace, 1/2" M NPT, 3704cfm

Catalog Page 0