657-600-0865 | support@kddepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: Power Vented, 200, 000 BtuH Heating Capacity Output, Side
Gas-Fired Duct Furnace: Power Vented, 200, 000 BtuH Heating Capacity Output, Side

Product Image

Gas-Fired Duct Furnace: Power Vented, 200, 000 BtuH Heating Capacity Output, Side

Manufacturer: DAYTON
Mfr. Model # 6RJX5
In Stock
$4,853.00 Save 15%
$4,102.68 /each
Earn 4102 points for this item ($41.02 for your next purchase!) REGISTER NOW TO EARN!
40 days
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: Power Vented, 200, 000 BtuH Heating Capacity Output, Side
DAYTON Gas-Fired Duct Furnace: Power Vented, 200, 00...
Mfr # 6RJX5
$4,102.68
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Should Sales be Restricted by Region? N
Standards ETL Certified
Fuel Type Natural Gas
Indoor Air Discharge Width 29-1/4 in
Ozone Depleting Substance N
Air Flow @ 80(F) Rise 2,300 cfm
Venting Vented
Heating Capacity Output 200,000 BtuH
Overall Height 37-3/4 in
Is this a Hazardous Material Product? N
Heating Method Fan Forced
Indoor Air Discharge Height 19 in
CEC Title 20 Applicable Y
Manufacturers Warranty Length 1 yr
Safety Data Sheet (SDS) Applicable? N
Mounting Height 8 ft
Heater Voltage 115 V AC
Air Flow 6173 cfm
Flue Diameter 5 in
Gas Connection Size 3/4 in
Heat Exchanger Gauge 20 ga
Frequency 60 Hz
Thermostat Included Thermostat Not Included
Burner Air Inlet Size 5 in
Air Flow @ 65(F) Rise 3,000 cfm
Contains California Prop 65 Reproductive Toxicant N
Primary Heat Exchanger Material 409 Stainless Steel
Freight Class Code 18
Required Air Flow 2,315 cfm
CEC Title 20 Compliant? Y
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Overall Depth 37 in
Vent Type Power
Overall Width 31-5/8 in
Combustion Type Open Combustion
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Gas Connection Type Male NPT
Contains California Prop 65 Carcinogen N
Max. External SP 0.9" WC
Air Temperature Rise [Number] 30 Degrees F
EnvironmentallyPreferable_Indicator N
Heating Capacity Input 250,000 BtuH
CEC Title 20 MAEDbS Certified Y
Storage Protection Code A
Maximum Amperage 1.9 A
Furnace Type Power Vented
Product Powered by Fossil Fuel N
Ignition Type Direct Spark
Service Access Location Side
Mfr. Model # 6RJX5
Description

Gas Fired Dct Furnace, 3/4" M NPT, 6173cfm

Catalog Page 0