657-600-0865 | support@kddepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: Power Vented Separated Combustion, Bottom, 822 cfm Required Air Flow
Gas-Fired Duct Furnace: Power Vented Separated Combustion, Bottom, 822 cfm Required Air Flow

Product Image

Gas-Fired Duct Furnace: Power Vented Separated Combustion, Bottom, 822 cfm Required Air Flow

Manufacturer: DAYTON
Mfr. Model # 6RJY6
In Stock
$5,118.00 Save 14%
$4,424.46 /each
Earn 4424 points for this item ($44.24 for your next purchase!) REGISTER NOW TO EARN!
40 days
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: Power Vented Separated Combustion, Bottom, 822 cfm Required Air Flow
DAYTON Gas-Fired Duct Furnace: Power Vented Separate...
Mfr # 6RJY6
$4,424.46
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Combustion Type Separated Combustion
Air Flow 2469 cfm
Venting Vented
Maximum Amperage 1.9 A
Required Air Flow 822 cfm
Service Access Location Bottom
Air Flow @ 80(F) Rise 1,000 cfm
Fuel Type Natural Gas
Is this a Hazardous Material Product? N
Indoor Air Discharge Width 15-1/2 in
Thermostat Included Thermostat Not Included
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Standards ETL Certified
Mounting Height 8 ft
Overall Width 17-7/8 in
Heating Capacity Input 100,000 BtuH
Furnace Type Power Vented Separated Combustion
Contains California Prop 65 Reproductive Toxicant N
Overall Height 36 in
Air Temperature Rise [Number] 30 Degrees F
Heating Method Fan Forced
Should Sales be Restricted by Region? N
Contains California Prop 65 Carcinogen N
Ozone Depleting Substance N
Heating Capacity Output 80,000 BtuH
Burner Air Inlet Size 5 in
Indoor Air Discharge Height 19 in
Max. External SP 2.03" WC
EnvironmentallyPreferable_Indicator N
Gas Connection Size 1/2 in
Heater Voltage 115 V AC
Freight Class Code 19
Overall Depth 40 in
Vent Type Power
Heat Exchanger Gauge 20 ga
Air Flow @ 65(F) Rise 1,100 cfm
CEC Title 20 Applicable Y
CEC Title 20 MAEDbS Certified Y
Storage Protection Code A
Frequency 60 Hz
CEC Title 20 Compliant? Y
Gas Connection Type Male NPT
Manufacturers Warranty Length 1 yr
Primary Heat Exchanger Material 409 Stainless Steel
Safety Data Sheet (SDS) Applicable? N
Product Powered by Fossil Fuel N
Flue Diameter 4 in
Ignition Type Direct Spark
Mfr. Model # 6RJY6
Description

Gas Fired Dct Furnace, 1/2" M NPT, 2469cfm

Catalog Page 0