Gas-Fired Duct Furnace: Power Vented Separated Combustion, Bottom, 822 cfm Required Air Flow
Gas-Fired Duct Furnace: Power Vented Separated Combustion, Bottom, 822 cfm Required Air Flow

Product Image

Gas-Fired Duct Furnace: Power Vented Separated Combustion, Bottom, 822 cfm Required Air Flow

Manufacturer: DAYTON
Mfr. Model # 6RJY6
In Stock
$5,118.00 Save 14%
$4,424.46 /each
Earn 4424 points for this item ($44.24 for your next purchase!) REGISTER NOW TO EARN!
40 days
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: Power Vented Separated Combustion, Bottom, 822 cfm Required Air Flow
DAYTON Gas-Fired Duct Furnace: Power Vented Separate...
Mfr # 6RJY6
$4,424.46
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Mounting Height 8 ft
Heat Exchanger Gauge 20 ga
Ignition Type Direct Spark
Product Powered by Fossil Fuel N
Should Sales be Restricted by Region? N
Indoor Air Discharge Width 15-1/2 in
Contains California Prop 65 Reproductive Toxicant N
Furnace Type Power Vented Separated Combustion
Ozone Depleting Substance N
Safety Data Sheet (SDS) Applicable? N
CEC Title 20 MAEDbS Certified Y
Gas Connection Size 1/2 in
Manufacturers Warranty Length 1 yr
Heating Capacity Output 80,000 BtuH
Overall Height 36 in
CEC Title 20 Applicable Y
Air Flow 2469 cfm
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Thermostat Included Thermostat Not Included
Indoor Air Discharge Height 19 in
Freight Class Code 19
Venting Vented
Air Temperature Rise [Number] 30 Degrees F
Heating Method Fan Forced
Primary Heat Exchanger Material 409 Stainless Steel
Gas Connection Type Male NPT
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Maximum Amperage 1.9 A
Service Access Location Bottom
Fuel Type Natural Gas
Required Air Flow 822 cfm
CEC Title 20 Compliant? Y
Flue Diameter 4 in
Heater Voltage 115 V AC
Vent Type Power
Storage Protection Code A
Max. External SP 2.03" WC
Overall Depth 40 in
Air Flow @ 80(F) Rise 1,000 cfm
Frequency 60 Hz
Air Flow @ 65(F) Rise 1,100 cfm
Combustion Type Separated Combustion
Contains California Prop 65 Carcinogen N
Is this a Hazardous Material Product? N
Heating Capacity Input 100,000 BtuH
EnvironmentallyPreferable_Indicator N
Standards ETL Certified
Burner Air Inlet Size 5 in
Overall Width 17-7/8 in
Mfr. Model # 6RJY6
Description

Gas Fired Dct Furnace, 1/2" M NPT, 2469cfm

Catalog Page 0