Fluke i1000s 1000 Amp AC Current Clamp Safety Rating 600V rms. CAT III per IEC 1010-02-032
In Stock
$935.00
Save 0%
$932.66
/each
Earn 932 points for this item
($9.32 for your next purchase!)
REGISTER NOW TO EARN!
Ships from the manufacturer in about 20 business days
Request quantity discount pricing
You're Viewing
FLUKE Fluke i1000s 1000 Amp AC Current Clamp Safety...
Mfr # I1000S
$932.66
Customers Also Viewed
No related products found.
Product Details
| Brand | FLUKE |
| Mfr. Model # | I1000S |
| Global Industrial Part # | M1502161 |
| UPC | 095969090476 |
| Color | Red |
| Weight | 3 lb |
| Unit of Measure | EA |
| Country of Origin | US |
| Ships Via | Parcel |
| Freight Class | 100 |
| Lead Time | 20 business days |
| Returnable | Yes |
| California Prop 65 | Warning applies |
| UNSPSC | 41113678 |
| Current Range | 100mA to 1000 Arms |
| Basic Accuracy 48Hz to 65Hz | 10A Range +/- 3% of reading + 0.1A, 100mV/A output 100A Range +/- 2% of reading + 0.5A, 10mV/A output 1000A Range +/- 1% of reading + 1A, 1mV/A output |
| Bandwidth | 5Hz to 100kHz |
| Working Voltage | 600V AC rms |
| Maximum Conductor Size | 54 mm (2.13 inch) diameter |
Description
The Fluke model I1000S is a portable 1000 arms oscilloscope probe intended for use in industrial and power environments. The unit permits analysis and measurement of current waveforms and harmonics. Millivolt output proportional to current magnitude allows for direct display of the waveform on an oscilloscope via a coaxial cable terminated with an insulated bnc connector.
Features
- Current Range: 100mA to 1000 Arms
- Basic Accuracy 48Hz to 65Hz: 10A Range +/- 3% of reading + 0.1A, 100mV/A output 100A Range +/- 2% of reading + 0.5A, 10mV/A output 1000A Range +/- 1% of reading + 1A, 1mV/A output
- Bandwidth: 5Hz to 100kHz
- Working Voltage: 600V AC rms
- Maximum Conductor Size: 54 mm (2.13 inch) diameter
- Safety Rating: 600V rms. CAT III per IEC 1010-02-032
- Current Range: 100mA to 1000 Arms
- Basic Accuracy 48Hz to 65Hz: 10A Range +/- 3% of reading + 0.1A, 100mV/A output 100A Range +/- 2% of reading + 0.5A, 10mV/A output 1000A Range +/- 1% of reading + 1A, 1mV/A output
- Bandwidth: 5Hz to 100kHz
- Working Voltage: 600V AC rms
- Maximum Conductor Size: 54 mm (2.13 inch) diameter