REED Compact Digital Multimeter with Non-Contact Voltage Detector
You're Viewing
GLOBAL TEST SUPPLY LLC REED Compact Digital Multimeter with Non-Cont...
Customers Also Viewed
No related products found.
Product Details
| Brand | GLOBAL TEST SUPPLY LLC |
| Mfr. Model # | R5099 |
| Global Industrial Part # | B3161516 |
| UPC | 800837005380 |
| Color | Blue |
| Weight | 0.5 lb |
| Length | 9 in |
| Width | 7 in |
| Height | 5 in |
| Unit of Measure | EA |
| Country of Origin | CN |
| Ships Via | Parcel |
| Freight Class | 250 |
| Lead Time | 1 business day |
| Returnable | Yes |
| UNSPSC | 41113630 |
Description
This versatile autoranging digital compact-sized multimeter measures ac/dc voltage and current resistance capacitance frequency diode and continuity. It also features a built-in non-contact voltage detector to quickly detect live voltage on electrical circuits found in residential commercial and industrial buildings.
Features
- Measures ac/dc voltage and current resistance capacitance frequency diode and continuity
- Built-in non-contact voltage detector and double molded plastic housing
- 4000-count backlit LCD display
- Low battery indicator and auto shut-off (after 30 minutes)
- Cat III 600v safety rating
- Resistance
- Range 400Ω 4 40 400KΩ 4 40MΩ
Accuracy 400Ω 4 40 400KΩ ±(1% rdg. + 5 dgt.)mΩ ±(1.2% rdg. + 10 dgt.)40MΩ ±(2% rdg. + 10 dgt.)
Resolution 0.1 1 10 100Ω 1 10KΩ
Capacitance
Range 50 500NF 5 50 100µf
Accuracy 50NF ±(4% rdg.+ 30 dgt.)500NF ±(3% rdg. + 15 dgt.)5 50 100µf ±(4% rdg. + 10 dgt.)
RESOLUTION0.01 0.1 1 10 100NF
Frequency
RANGE9.999HZ to 60KHZ
Accuracy ±(0.1% rdg. + 5 dgt.)
Resolution 0.001HZ to 0.001MHZ
Continuity check audible signal if resistance 10Ω
Operating temperature 32 to 104°f (0 to 40°c)
Storage temperature 14 to 122°f (-10 to 50°c)
What's Included
- With the reed R5099
- Compact multimeter
- Test leads
- Batteries(2 x aaa)
- Ideal applications for the reed R5099
- Testing batteries
- Testing household wiring
- Testing electric motors
- Testing power supplies
- Ac/dc voltage
- Range AC 4 40 400 600VDC 400MV 4 40 400 600v
- Accuracy AC 4 40v ±(1.2% rdg. + 5 dgt.)400 600v ±(2% rdg.+ 10 dgt.)DC 400MV ±(1% rdg.+ 8 dgt.)4 40v ±(0.5% rdg.+ 5 dgt.) 400 600v ±(0.8% rdg.+ 5 dgt.)
- Resol